Compare Products

Hide

Clear All

VS

Picture

RG-S2928G-E V3, 24-port Gigabit access switch, 4 Gigabit uplink ports

Full gigabit access to LANs in large enterprises and institutions, such as government buildings, universities, and large enterprises, etc.

Models
Series
Highlight Features
  • VSU virtualization technology, flexible networking, super experience.
  • Real-time monitoring of security protection policies ensures continuous network robustness.
  • Fanless design, natural heat dissipation, silent and energy-saving.
  • Multiple management options Network maintenance is simple and effective.
Sales Enquiry
Features
Comprehensive Security Policies
The RG-S2900G-E V3 Series effectively prevents and controls virus spread and hacker attacks with various inherent mechanisms such as anti-DoS attacks, hacker IP scanning, illegal ARP packets checking and multiple hardware ACL policies.
Industry-leading CPU protection mechanism: The CPU Protect Policy (CPP) provides policies for protecting the CPU of a switch. In network environments, various attack packets spread, which may cause high CPU usages of the switches, affect protocol running and even difficulty in switch management. To this end, switch CPUs must be protected, that is, traffic control and priority-based processing must be performed for various incoming packets to ensure the processing capabilities of the switch CPUs.
o CPP can effectively prevent malicious attacks in the network and provide a clean environment for legitimate protocol packets.
o CPP is enabled by default. It provides protection during the entire operation of switches.
IP/MAC binding: Implement flexible binding of a port or the system to the IP address and MAC address of users, strictly limiting user access on a port or in the entire system.
DHCP snooping: Allow DHCP responses from trusted ports only; based on DHCP listening and by monitoring ARP dynamically and checking the user IP address, directly discard illegal packets inconsistent with binding entries to effectively prevents ARP frauds and source IP address frauds.
Secure Shell and SNMPv3: Secure Shell (SSH) and Simple Network Management Protocol v3 (SNMPv3) cryptographic network protocol ensure the security of management information. Provides services such as multi-element binding, port security, time-based ACL and bandwidth rate limiting to block unauthorized users.
NFPP: Network Foundation Protection Policy (NFPP) provides guards for switches. Malicious attacks are always found in the network environment. These attacks bring heavy burdens to switches, resulting in high CPU usage and operational troubles. These attacks are as follows:
o Denial of Service (DoS) attacks may consume lots of memory, entries, or other resources of a switch, which will cause system service termination.
o Massive attack traffic is directed to the CPU, occupying the entire bandwidth of the CPU. In this case, normal protocol traffic and management traffic cannot be processed by the CPU, causing protocol flapping or management failure. The forwarding in the data plane will also be affected and the entire network will become abnormal.
NFPP can effectively protect the system from these attacks. Facing attacks, NFPP maintains the proper running of various system services with a low CPU load, thereby ensuring the stability of the entire network.


Virtual Switch Unit (VSU)

The Virtual Switch Unit technology, or VSU in short, enables interconnection of several physical devices by virtualizing them into one logical device. The logical device uses one single IP address, Telnet process, command-line interface (CLI), and enables auto version inspection and configuration. From the user perspective, the benefits are multiplied work efficiency and enhanced user experience of several devices operating at the same. And they only have to manage one device. The VSU technology also offers multiple benefits below:
Easy management: Administrators can centrally manage all the devices at the same time. It is no longer necessary to configure and manage the switches one by one.
Simplified typology: The VSU is regarded as one switch in the network. By connection of aggregation link and peripheral network devices, MSTP protocol is unnecessary as there is no Layer 2 loop network. All protocols operate as one switch. 
Millisecond failover: The VSU and peripheral devices are connected via the aggregation link. Upon failure event of any device or link, failover to another member link requires only 50 to 200ms.
Exceptional scalability: The network is hot swappable, any devices leaving or joining the virtualized network cause zero impact on other devices.

High Reliability
The RG-S2900G-E V3 Series supports spanning tree protocols of 802.1d, 802.1w, and 802.1s to ensure rapid convergence, improves fault tolerance capabilities, ensures stable running of networks and load balancing of links, and provides redundant links.

Virtual Router Redundant Protocol (VRRP): Effectively ensure network stability.
Rapid Link Detection Protocol (RLDP): Detect the connectivity of links and whether an optical fiber link is normal from both ends, and supports the loop detection function based on the port to prevent network faults caused by loops generated by the connection of devices such as hubs to ports.
Ethernet Ring Protection Switching (ERPS) (G.8032): Implements loop blocking and link recovery on the master device. Other devices directly report link status to the master device. Without passing through other standby devices, the failover time of loop interruption and recovery is hence faster than STP. The ERSP’s link failover rate can be completed within milliseconds under ideal conditions.
Rapid Ethernet Uplink Protection Protocol (REUP): When Spanning Tree Protocol (STP) is disabled, the Rapid Ethernet Uplink Protection Protocol (REUP) can provide basic link redundancy through the rapid uplink protection function and provide faster subsecond-level fault recovery than STP.

Software-Defined Networking (SDN)
With the all-new hardware architecture and Ruijie’s latest RGOS11.X modular operating system, the RG-S2900G-E V3 Series fully supports OpenFlow 1.3. in collaboration with Ruijie’s SDN controller, it forms a large-scale Layer 2 networking architecture with ease. Smooth upgrade of the whole network to a SDN one is also enabled. The switch series hence greatly simplifies the network management and minimizes network deployment savings.

Energy Efficiency
The RG-S2900G-E V3 Series adopts next-gen hardware architecture with a highly energy-saving circuit design and component selection. The device achieves a marked reduction in energy consumption. In addition to maximized energy saving, the RG-S2900G-E V3 Series also significantly lowers noise pollution. All models in the series deploy variable-speed axial fans, which support intelligent speed adjustment based on the current ambient temperature. All the features enable the switches to work smoothly and reduce power consumption and noise pollution at the same time.  
The RG-S2900G-E V3 Series also supports auto-power-down mode. When an interface is down for a certain period of time, the system will automatically power it down for extra energy efficiency. EEE energy-saving mode is another feature highlight. The system will automatically turn an idle port into energy-saving mode. When there is a new packet, the system will issue listening streams to the port to resume service. 

Easy Network Maintenance
The RG-S2900G-E V3 Series supports abundant features such as SNMP V1/V2/V3, RMON, Syslog, and logs and configuration backup using USB for routine diagnosis and maintenance. Administrators can use a wide variety of methods for easier management and such include CLI, web management, Telnet, CWMP(TR069),etc.
 The RG-S2900G-E V3 Series fully supports RG-SNC (Smart Network Commander) which is a network management system launched by Ruijie Networks especially designed for network performance management and configuration. With a friendly browser UI, the SNC provides an extensive array of features such as network topology display, device management, performance monitoring, configuration & software management, real-time alarm and log & report management.

Design For Durability
In the corrosive gas, high humidity environment, electronic products will accelerate corrosion, reliability and lifetime will be shortened, However, deployment environments of access switch are different, there may be lack of temperature and humidity regulation and close to the source of pollution or the sea. Through the design for durability, RG-S29E V3 series switches can operate stably in a variety of deployment environments.
Fanless design: If the air flow on the surface of the electronic product is too fast, it will increase the degree of gas corrosion of the equipment and shorten the service life of the equipment. For low-power products, fanless design is the most effective anti-corrosion measures. The RG-S2928G-E uses a fanless design to reduce corrosive gases and dust ingress.
Spesifikasi

Model

RG-S2928G-E V3

RG-S2952G-E V3

Ports

24 10/100/1000BASE-T ports
4 1G SFP ports (non-combo)

48 10/100/1000BASE-T ports
4 1G SFP ports (non-combo)

Fan Slots

Fanless

Fixed

Management Ports

1 console port

Switching Capacity

56 Gbps

104 Gbps 

Packet Forwarding Rate

96 Mpps

78 Mpps

Port Buffer

1.5MB

ARP Table

1,000

MAC Address

Up to 16K

Routing Entries

500

IP Host Entries
(IPv4/IPv6)

500 (IPv4/IPv6)

ACL Entries

Up to 1,500

ACL

Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect

QoS

802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities

VLAN

4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP

QinQ

Basic QinQ, Flexible QinQ, 1:1 VLAN switching

Link Aggregation

AP, LACP, Flow balance

Port Mirroring

Many-to-one mirroring, One-to-Many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN

Spanning Tree Protocols

IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC filter, TC protection, LOOP guard, ROOT guard

DHCP

DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay

Multiple Spanning Tree Protocol (MSTP) Instances

64

Maximum Aggregation Port (AP)

Up to 128

Multicast

IGMP v1/v2/v3 snooping, IGMP SGVL/IVGL, IGMP filter, IGMP fast leave, MLD snooping v1/v2

SDN

OpenFlow 1.0, future support OpenFlow 1.3

EEE Format

Support IEEE 802.3az standard

G.8032

Support

L2 Features

MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast storm control, IGMP v1/v2/v3 snooping, IGMP SGVL/IVGL, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel

Layer 2 Protocols 

IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s

Security

Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection

Layer 3 Features

IPv4 static routing, IPv6 static routing, RIP, RIPng, OSPFv2/v3, ARP proxy, Neighbor Discovery,VRRP

Layer 3 Protocols (IPv4) 

Static routing, RIP, RIPng, OSPFv2/v3

IPv4 Features

Ping, Traceroute

IPv6 Features

0-64 any length mask, ICMPv6, Neighbor Discovery, Manually configure local address, Automatically create local address,  IPv6 Ping, IPv6 Tracert, IPv6 extender option head,VRRP v3

Basic IPv6 Protocols

IPv6 addressing, Neighbor Discovery (ND), IPv6 ACL, ICMPv6, IPv6 Ping, IPv6 Tracert

IPv6 Routing Protocols

Static routing, RIPng, OSPFv3

VSU (Virtual Switch Unit)

Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended)

Zero Configuration

CWMP(TR069)

Reliability

RAS
VSU (virtualization technology for virtualizing multiple devices into 1); GR for RIP/OSPF;  ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)

Manageability

SNMPv1/v2c/v3, CLI (Telnet/Console), RMON (1, 2, 3, 9), SSH, Syslog/Debug, RSPAN/ERSPAN, NTP/SNTP, FTP, TFTP, Web, SFLOW,support cable detection and port sleep mode

Smart Temperature Control

Fanless

Auto fan speed adjustment; Fan malfunction alerts; Fan status check

Other Protocols

FTP, TFTP, DNS client, DNS static

Dimensions
(W x D x H) (mm)

440 × 260 × 43.6

Rack Height

1RU

Weight

≤3.5kg

≤4kg

MTBF

482560 hours

372690 hours

Lightning Protection

6KV

Power Supply

AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50 to 60Hz

HVDC input:
Input voltage range: 192V to 290V DC

Power Consumption 

≤24W

≤40W

Temperature

Operating temperature: 0°C to 50°C

Storage temperature: -40°C to 70°C

Humidity

Operating humidity: 10% to 90%RH

Storage humidity: 5% to 95%RH

Operating Altitude

-500m to 5,000m

Safety Standards

IEC 60950-1,EN60950-1

Emission Standards

EN 300 386, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11

Show More
Resources All Resources
Learn about Products or Solutions
Installation
Software and Configuration
Order Information

Model

Description

RG-S2928G-E V3

24 10/100/1000BASE-T ports

4 1G SFP ports (non-combo)

RG-S2952G-E V3

48 10/100/1000BASE-T ports

4 1G SFP ports (non-combo)

Mini-GBIC-GT

1000BASE-GT mini GBIC Transceiver

MINI-GBIC-SX-MM850

1000BASE-SX mini GBIC Transceiver (850nm)

MINI-GBIC-LX-SM1310

1000BASE-LX mini GBIC Transceiver (1310nm)

MINI-GBIC-LH40-SM1310

1000BASE-LH mini GBIC Transceiver (1310nm, 40km)

MINI-GBIC-ZX50-SM1550

1000BASE-ZX mini GBIC Transceiver (1550nm, 50km)

MINI-GBIC-ZX80-SM1550

1000BASE-ZX mini GBIC Transceiver (1550nm, 80km)

MINI-GBIC-ZX100-SM1550

1000BASE-ZX mini GBIC Transceiver (1550nm, 100km)

GE-SFP-LX20-SM1310-BIDI

1000BASE-LX, SFP Transceiver, BIDI-TX1310/RX1550,20km,LC

GE-SFP-LX20-SM1550-BIDI

1000BASE-LX, SFP Transceiver, BIDI-TX1550/RX1310,20km,LC

GE-SFP-LH40-SM1310-BIDI

1000BASE-LH, SFP Transceiver, BIDI-TX1310/RX1550,40km,LC

GE-SFP-LH40-SM1550-BIDI

1000BASE-LH, SFP Transceiver, BIDI-TX1550/RX1310,40km,LC

 

Show More
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Kontakt

Kontakt

How can we help you?

Kontakt

Get an Order help

Kontakt

Get a tech support