128 x 400GE ports and 2 x 10GE ports, RDLB and GDLB of the AI-Fabric solution to improve the bandwidth and shorten the AI training time in AIGC intelligent computing scenarios
System Specifications |
RG-S6990-128QC2XS |
Switching capacity |
102.4 Tbps |
Packet forwarding rate |
21,000 Mpps |
Port Specifications |
|
Service port |
128 x 200GE/400GE QSFP112 ports 2 x 1GE/10GE SFP+ ports |
Management port |
1 x RJ45 console port 1 x RJ45 MGMT port |
USB port |
1 x USB 2.0 port (Type A connector) |
Slot |
Four power module slots Five fan module slots |
Dimensions and Weight |
|
Dimensions (W x D x H) |
446 mm x 800 mm x 173.6 mm (17.56 in. x 31.5 in. x 6.84 in.) |
Height |
4 RU |
Weight |
Chassis only: 36.15 kg (79.7 lbs) Fully system: 43 kg (94.8 lbs) |
Mounting option |
Rack-mount |
Power Supply and Consumption |
|
Power consumption |
Max: 3180 W Typical: 2339 W Static: 434 W |
Power input |
RG-PA1600II-F (AC input) Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50/60 Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 12 A (100 V AC to 127 V AC) 9.5 A (200 V AC to 240 V AC) Power connector: C14
RG-PA1600II-F (HVDC input) Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated input current: 9.5 A Power connector: C14 |
Environment and Reliability |
|
Temperature |
Operating temperature: 0°C to 40°C (32°F to 104°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1,800 m (5,905.51 ft) to 5,000 m (16,404.20 ft), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft) increase in elevation. |
Humidity |
Operating humidity: 10% RH to 90% RH (non-condensing) Storage humidity: 5% RH to 95% RH (non-condensing) |
Altitude |
Operating altitude ≤ 5,000 m (16,404.20 ft) Storage altitude ≤ 5,000 m (16,404.20 ft) |
Cooling |
Air cooling, front-to-rear airflow (port-side intake) |
* indicates that the feature will be available in the future.
Software Specifications |
RG-S6990-128QC2XS |
Layer 2 protocols |
IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
Layer 3 protocols (IPv4) |
BGP4, OSPFv2, RIPv1, RIPv2, LPM Routing, Policy-based Routing, Route-policy, ECMP, WCMP, VRRP |
Basic IPv6 protocols |
Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS |
IPv6 features |
Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ |
Data center features |
VXLAN*, BGP-EVPN RDMA PFC, ECN PFC deadlock prevention AI-powered ECN* ECN overlay* RDLB, GDLB |
Visualization |
Telemetry sFlow |
QoS |
IEEE 802.1p, DSCP, and ToS mapping |
High redundancy design |
GR for RIP/OSPF/BGP, BFD, DLDP, REUP, Rapid Link Detection Protocol (RLDP), 2 + 2 power redundancy, fan redundancy, and hot swapping of line cards and power modules |
Security features |
Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), RADIUS/TACACS, IPv4/IPv6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet from specified IP addresses, broadcast packet suppression, and hierarchical user management |
Management mode |
SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, temperature alarm |
Other protocols |
DHCP Client, DHCP Relay, DHCP Server, DNS Client, ARP Proxy, and Syslog |
* indicates that the feature will be available in the future.
Take the following steps to configure an RG-S6990-128QC2XS:
Models marked with asterisks (*) in the ordering information will be available in the future.
Model |
Description |
RG-S6990-128QC2XS |
Fixed 128 x 400GE ports, 2 x 10GE ports, four power module slots, and five fan module slots |
RG-PA1600II-F |
Power module, hot swappable 2 + 2 redundancy, front-to-rear airflow |
FAN80-180F |
Fan module, hot swappable 4 + 1 redundancy, front-to-rear airflow |
Model |
Description |
GE-SFP-LX20-SM1550-BIDI |
1GE LX transceiver, SFP form factor, BIDI LC, 1550 nm, 20 km (65,616.80 ft.) over SMF |
GE-SFP-LX20-SM1310-BIDI |
1GE LX transceiver, SFP form factor, BIDI LC, 1310 nm, 20 km (65,616.80 ft.) over SMF |
GE-SFP-LX03-SM1550-BIDI-I |
1GE LX transceiver, SFP form factor, BIDI LC, 1550 nm, 3 km (9,842.52 ft.) over SMF |
GE-SFP-LX03-SM1310-BIDI-I |
1GE LX transceiver, SFP form factor, BIDI LC, 1310 nm, 3 km (9,842.52 ft.) over SMF |
GE-SFP-LH40-SM1550-BIDI |
1GE LH transceiver, SFP form factor, BIDI LC, 1550 nm, 40 km (131,233.59 ft.) over SMF |
GE-SFP-LH40-SM1310-BIDI |
1GE LH transceiver, SFP form factor, BIDI LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
MINI-GBIC-ZX80-SM1550 |
1GE ZX transceiver, SFP form factor, duplex LC, 1550 nm, 80 km ( 262,467.20 ft.) over SMF |
Model |
Description |
XG-SFP-AOC5M |
10GE AOC cable, SFP+ form factor, 5 m (16.40 ft.) |
XG-SFP-LR-SM1310 |
10GE LR transceiver, SFP+ form factor, duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
XG-SFP-iLR-SM1310-I |
10GE LR transceiver, SFP+ form factor, duplex LC, 1310 nm, 1.4 km (4,593.18 ft.) over SMF |
Model |
Description |
100G-QSFP-ER4-SM1310 |
100GE ER4 transceiver, QSFP28 form factor, duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
100G-QSFP-iLR4-SM1310 |
100GE iLR4 transceiver, QSFP28 form factor, duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
100G-QSFP-LR4-SM1310 |
100GE LR4 transceiver, QSFP28 form factor, duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
100G-QSFP-SR-MM850 |
100GE SR transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over OM4 MMF |
Model |
Description |
200G-Q56-SR4-MM850(D) |
200GE SR4 transceiver, QSFP56 form factor, MPO12/APC, 850 nm, 100 m (328.08 ft.) over OM4 MPO MMF, CMIS-compliance |
200G-Q56-SR4-MM850 |
200GE SR4 transceiver, QSFP56 form factor, MPO12/APC, 850 nm, 100 m (328.08 ft.) over OM4 MPO MMF, SFF-8636-compliance |
Model |
Description |
400G-Q112-DR4-SM1310 |
400GE DR4 transceiver, QSFP112 form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF |
400G-Q112-VR4-MM850 |
400GE VR4 transceiver, QSFP112 form factor, MPO-12 APC, 850 nm, 50 m (164.04 ft.) over OM4 MMF |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Kontakt
How can we help you?