–40°C to 85°C operating temperature range and IP40 protection for application in various tough environments
Less than 20 ms failover, ensuring more reliable user data transmission
More than 30 years mean time between failures (MTBF)
Optimized network deployment and low network construction costs
Flexible installation modes of DIN-rail
–40°C to 85°C operatingtemperature range
Enjoying superb network experience anywhere.
Withstanding extremely gritty environments. Preventing particles with 1mm diameter or above from entering the device.
No pressure from network faults: ERPS achieves less than 20 ms failover
Improved stability and management efficiency: VSU for managing multiple devices as one
All-round device and network security protection: CPP and NFPP
Security features (anti-attack and secure access)
Adaptation to habits of different users: Diverse management features (CLI, and NMS software)
This solution is designed for city-wide IP Surveillance Integrated Network and Monitoring, to solve problems such as monadic front-end access mode, low reliability, high costs, and poor transmission network stability and difficult OAM at the back end.
This is an overall solution from front-end access to back-end transmission, helping the development of safe cities.
Durable aluminum case
Same size as a Mini iPad
1 kg only
Suitable for access video surveillance scenarios, such as in rail transport, traffic checkpoints, campuses, power plants and mines
Finned surface design increases the air contact area and enhances the heat dissipation effect;
Aluminum chassis, metal protruded boss, metal blocks, and thermally conductive adhesives ensure that heat generated by components with high heat emission, such as the MAC/PHY of the primary chip and switched-mode power supply (SMPS), is transferred to the chassis to improve the heat dissipation efficiency, which is four times the efficiency of iron-made switches;
Industrial components are used to ensure strong high-temperature resistance;
The efficient industrial AC-DC SMPS improves the efficiency by more than 15% compared with that of common SMPS, reducing power loss and decreasing heat.
The port power design is adopted, which overhauls the conventional power design and prevents power cable disconnection in scenarios with strong vibration, such as rail switching, highways, traffic checkpoints and workshops.
Relay alarm interfaces are reserved in power interfaces, ensuring connection to the relay alarm on the customer end.
Strong electromagnetic radiation resistance and minimized electromagnetic interference ensure coping easily with special environments where industrial switches are located and compliance with the common international standard IEC61000.
Multiple devices are managed as one to ensure higher management efficiency (< 20 ms)
User investments are protected to the greatest extent possible, and the link utilization is higher
The fault convergence time is less than or equal to 50 ms, ensuring more reliable networks
Supporting intersecting rings and tangent rings with less than 50 ms convergence time
Up to 50 devices supported in a single ring and a maximum of 256 HD cameras supported
Various security access mechanisms are supported to prevent 802.1X authentication and Web authentication attacks.
MAC authentication and ACL delivery < 20 ms
MAC address + port + IP address binding
ARP attack prevention
CPP + NFPP
When back-end multi-level servers obtain image data from the front-end cameras, multicast packets are used to save the network bandwidth and enhance security of video packets. Unicast: Indicates the common one-to-one transmission mode. To transmit the same image to six servers, six packets are required, which wastes network bandwidth. Multicast: When packets are transmitted on the industrial switch, six packets are simplified into two. Packets are copied only to the required node, thus saving bandwidth.
Model | RG-IS2712G-DC | RG-IS2712G | RG-IS2706G |
Fixed Ports | 8 10/100/1000BASE-T ports 4 1000BASE-X SFP ports (100M not supported) | 4 10/100/1000BASE-T ports 2 1000BASE-X SFP ports (100M not supported) |
|
Management Port | 1 console port |
||
Switching Capacity | 36Gbps | 18Gbps |
|
Forwarding Rate | 26.7Mpps | 13.4Mpps |
|
802.1q VLAN | 4K |
||
Operating Temperature | -40 to 85°C |
||
Operating Humidity | 5 to 95%RH |
||
Protection Rating | IP40 |
||
MTBF | >30 years |
||
Electromagnetic Interference | ESD (IEC 61000-4-2) Level 4 (8K/15K) RS (IEC 61000-4-3) Level 3 (10V/m) EFT (IEC 61000-4-4) Level 3 (1V/2V) CS (IEC 61000-4-6) Level 3 (10V/m) PFMF (IEC 61000-4-8) Level4 (30A/m) Surge (IEC 61000-4-5) Level 4+ (6KV/2KV) DIP (IEC 61000-4-11) Level3 (10V) |
||
L2 Protocols | G.8032 (ERPS), IEEE802.1ag, IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q, IEEE802.1d, IEEE802.1w, IEEE802.1s, IGMP Snooping v1/v2/v3 |
||
ACL | Standard IP ACL (hardware ACL based on IP address) Extended IP ACL (hardware ACL based on IP address and TCP/UDP port number) Extended MAC ACL (hardware ACL based on source MAC address, destination MAC address and optional Ethernet type) Expert ACL (hardware ACL based on flexible combination of VLAN number, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, time, etc.) |
||
IPv6 ACL & QoS | Support IPv6 ACL and IPv6 QoS based on source/destination IPv6 address and port Priority queue: 8 |
||
Security | Binding of IP, MAC and port Binding of IPv6, MAC and port Filter rogue MAC address MAC-based and port-based 802.1x Web authentication and concurrent 802.1x, ARP-Check and ACL ARP-Check, DAI Speed limit on packet transmission Broadcast storm suppression Administrator hierarchy and password protection AAA authentication for device login management (IPv4/IPv6) SSH, BPDU Guard |
||
IP Routing | Default routing, static routing between host and directly connected network segments |
||
IPv6 Protocols | IPv6 address assignment, Neighbor Discovery (ND), ICMPv6, IPv6 Ping, IPv6 Tracert |
||
Management | SNMPv1/v2c/v3, CLI (Telnet/Console), RMON (1, 2, 3, 9), SSH, Syslog, NTP/SNTP, web |
||
Dimensions (W×H×D) (mm) | 52 x 115 x 160 |
||
Installation Mode | DIN rail-mounted |
||
Power Supply | DC input: Rated voltage: 24VDC, 48VDC Maximum voltage range: 18VDC to 72VDC Maximum current: 1.0A Two power supplies are supported for 1+1 power redundancy. | AC Input: Nominal voltage range: 100-240V Max voltage range: 90-264V Frequency: 50-60Hz Rated current: 0.4A HVDC input: Rated voltage range: 140VDC to 340VDC Maximum voltage range: 130VDC to 370VDC Rated current: 0.4A |
|
Power Consumption | ≤12W | ≤8W |
|
Heat Dissipation | Fanless design with high-efficiency heat sink |
||
Safety Standards | NA | IEC 60950-1,EN60950-1 |
|
Emission Standards | EN 300 386, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 |
Model | Description |
---|---|
RG-IS2712G-DC | 8-port 10/100/1000BASE-T, 4-port 1000BASE-X SFP (non-combo), built-in power supply, fanless design, aluminum case, support rail mount installation, DC input. |
RG-IS2712G | 8-port 10/100/1000BASE-T, 4-port 1000BASE-X SFP (non-combo), built-in power supply, fanless design, aluminum case, support rail mount installation, AC input. |
RG-IS2706G | 4-port 10/100/1000BASE-T, 2-port 1000BASE-X SFP (non-combo), built-in power supply, fanless design, aluminum case, support rail mount installation, AC input. |
Optional Accessories |
|
GE-SFP-LX20-SM1310-BIDI | SFP Gigabit BIDI optical module, TX1310/RX1550 (20km, LC) |
GE-SFP-LX20-SM1550-BIDI | SFP Gigabit BIDI optical module, TX1550/RX1310 (20km, LC) |
GE-SFP-LH40-SM1310-BIDI | SFP Gigabit BIDI optical module, TX1310/RX1550 (40km, LC) |
GE-SFP-LH40-SM1550-BIDI | SFP Gigabit BIDI optical module, TX1550/RX1310 (40km, LC) |
Mini-GBIC-GT | 1000BASE-TX, SFP Transceiver (100m) |
Mini-GBIC-SX-MM850 | 1000BASE-SX mini GBIC Transceiver (850nm) |
Mini-GBIC-LX-SM1310 | 1000BASE-LX mini GBIC Transceiver (1310nm) |
Mini-GBIC-LH40-SM1310 | 1000BASE-LH mini GBIC Transceiver (1310nm, 40km) |
Mini-GBIC-ZX50-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 50km) |
Mini-GBIC-ZX80-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 80km) |
Mini-GBIC-ZX100-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 100km) |
CON-DB9/RJ45-2M | Ruijie Console Cable RJ45-to-DB9 (2m) |