Virtualization for Demand-based Allocation
Virtual Switch Unit 3.0 (VSU)
The RG-S7800C Switch Series supports the Virtual Switch Unit 3.0 (VSU). The technology can virtualize 2 devices into one logical unit, which largely minimizes the number of network nodes and reduce maintenance workload. Superior 50~200ms link failover ensures smooth and uninterrupted transmission of key services. The RG-S7805C Series switch supports cross-device link aggregation for easy double uplink to server/switch, effectively maximizing bandwidth investment return.
Virtual Switch Device (VSD)
The RG-S7800C Switch Series supports VSD in which one device can be virtualized into multiple virtual units. Each virtual unit has a unique configuration management interface and independent hardware allocation (e.g. storage, TCAM and hardware forwarding table). All the features support restart with no impact on other virtual machines. Users can realize network resource allocation based on different needs. Resources of the core switch can hence be shared with other domains and users. With the enablement of both VSU3.0 and VSD, the switch satisfactorily delivers complete resource pooling.
Carrier-class Reliability
Redundant design of the RG-S7800C Switch Series key components delivers excellent protection: control engine power and fan modules all support 1+1 redundancy. All redundant components are hot-swappable to maximize reliability and availability. Hot patch technology is also supported to enable online upgrade.
Support GR for OSPF/IS-IS/BGP and BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing to enable the fast fault detection mechanism of different protocols. The feature minimizes the fault detection time to less than 50ms.
Multi-processing Modular Operating System
Since 1998, Ruijie has been investing on the R&D of modular operating system. The RG-S7800C Switch Series software platform is designed based on the next-generation RGOS 11.X multi-processing modular operating system to integrate the service features such as loosely coupled firewall, wireless and authentication into a unified cloud network operating system. The RG-S7800C Series software platform also supports full virtualization and offers rich data center and campus network features. The key availability indicators such as multi-processing modules, process backup and hot patch have reached the industry-leading level.
Excellent Energy Efficiency
The internal system is designed for low voltage power supply with high-efficiency modular power to form a more efficient power supply system. The multi-core CPU supports dynamic power management with all Ethernet copper ports implements the Energy-Efficient Ethernet (EEE) standard to save power under light load.
The smart fan supports 256 speed modulations with precise temperature control, energy saving and noise control. The device can function at high temperature for a long period of time or in harsh environment. The RG-S7800C Switch Series thereby helps clients to maximize savings on air conditioning.
Model | RG-S7805C | RG-S7808C |
Module Slots | 5(2 for control engines) | 8 (2 for control engines) |
Modular Power Slots | 2(for system power) | 6 (4 for system power; 2 for PoE power) |
Switching Capacity | 4800Gbps | 9600Gbps |
Packet Forwarding Rate | 7142.4Mpps | 14284.8Mpps |
Max. Number of 10GE Ports | Up to 24 | Up to 48 |
PoE | Non Support | Support |
ARP Table | Up to 20K | Up to 20K |
MAC Address | Up to 64K | Up to 64K |
Routing Entries | Up to 10K | Up to 10K |
Multicast Entries (IPv4/IPv6) | Up to 8K/4K | Up to 8K/4K |
ACL Entries | Up to 3,500 | Up to 3,500 |
VLAN | Up to 4K | Up to 4K |
QinQ | Basic QinQ, Flexible QinQ | Basic QinQ, Flexible QinQ |
Link Aggregation | AP, LACP | AP, LACP |
Port Mirroring | Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, SPAN, RSPAN, VLAN mirroring | Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, SPAN, RSPAN, VLAN mirroring |
Spanning Tree Protocols | Support STP, RSTP and MSTP | Support STP, RSTP and MSTP |
DHCP | Support DHCP relay, DHCP snooping, DHCP server, DHCP client | Support DHCP relay, DHCP snooping, DHCP server, DHCP client |
Multiple Spanning Tree (MST) Instances | 64 (not include default 0) | 64 (not include default 0) |
Maximum Aggregation Port (AP) | Up to 2,048 | Up to 2,048 |
Virtual Routing and Forwarding (VRF) Instances | Up to 1,000 | Up to 1,000 |
VSU (Virtual Switch Unit) | Up to 2 stack members | Up to 2 stack members |
VSD (Virtual Switch Device) | Up to 4 VSD units | Up to 4 VSD units |
L2 Features | Jumbo Frame, 802.1Q, STP, RSTP, MSTP, Super VLAN, GVRP, QinQ, Flexible QinQ, LLDP, ERPS (G.8032),MAC Based VLAN,Voice VLAN,RLDP | Jumbo Frame, 802.1Q, STP, RSTP, MSTP, Super VLAN, GVRP, QinQ, Flexible QinQ, LLDP, ERPS (G.8032) |
Layer 2 Protocols | IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, Jumbo Frame (9Kbytes), IEEE802.1ad (QinQ and flexible QinQ), GVRP | IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, Jumbo Frame (9Kbytes), IEEE802.1ad (QinQ and flexible QinQ), GVRP |
Layer 3 Features | ARP, IPv4/v6, PBR v4/v6 | ARP, IPv4/v6, PBR v4/v6 |
Layer 3 Protocols (IPv4) | Ping, Traceroute, Equal-Cost Multi-Path Routing (ECMP) | Ping, Traceroute, Equal-Cost Multi-Path Routing (ECMP) |
IPv4 Features | Static routing, RIP, OSPF, BGP4, ISIS, VRRP, Equal-cost routing, Policy-based routing, GRE tunnel | Static routing, RIP, OSPF, BGP4, ISIS, VRRP, Equal-cost routing, Policy-based routing, GRE tunnel |
IPv6 Features | Static routing OSPFv3, BGP4+, IS-ISv6, MLD, VRRPv3, Equal-cost routing,Policy-based routing, Manual tunnel, Auto tunnel, ISATAP tunnel, GRE tunnel | Static routing OSPFv3, BGP4+, IS-ISv6, MLD, VRRPv3, Equal-cost routing |
Basic IPv6 Protocols | DNS client v6, DHCP relay v6, DHCP v6 server, Telnet v6, TFTP client v6, FTP v6, NTP client v6, NTP server v6 | DNS client v6, DHCP relay v6, DHCP v6 server, Telnet v6, TFTP client v6, FTP v6, NTP client v6, NTP server v6 |
Routing Protocols | RIP, RIPng, OSPFv2/v3, BGP4, BGP4+, IS-ISv4/v6, Routing Policy | RIP, RIPng, OSPFv2/v3, BGP4, BGP4+, IS-ISv4/v6, Routing Policy |
IPv6 Tunnel Features | 6over4 Manual Tunnel, 6to4 Auto Tunnel, Manual Tunnel, Auto Tunnel, ISATAP Tunnel, IPv4 over IPv6 Tunnel, IPv6 over IPv4 Tunnel, GRE Tunnel(4 over 6), GRE Tunnel(6 over 4) | 6over4 Manual Tunnel, 6to4 Auto Tunnel, Manual Tunnel, Auto Tunnel, ISATAP Tunnel, IPv4 over IPv6 Tunnel, IPv6 over IPv4 Tunnel, GRE Tunnel(4 over 6), GRE Tunnel(6 over 4) |
Multicast | IGMP v1/v2/v3, IGMP snooping, IGMP proxy, Multicast routing protocols (PIM-DM, PIM-SM, PIM-SSM), MLD, Multicast static routing | IGMP v1/v2/v3, IGMP snooping, IGMP proxy, Multicast routing protocols (PIM-DM, PIM-SM, PIM-SSM), MLD, Multicast static routing |
G.8032 | Support | Support |
ACE Capacity | Up to 3,500 | Up to 3,500 |
ACL | Standard/Extended/Expert ACL; ACL 80; IPv6 ACL | Standard/Extended/Expert ACL; ACL 80; IPv6 ACL |
QoS | 802.1p, Queue scheduling mechanisms (SP, WRR, DRR, WFQ, SP+WFQ, SP+WRR, SP+DRR), RED/WRED, Input/output port-based speed limit | 802.1p, Queue scheduling mechanisms (SP, WRR, DRR, WFQ, SP+WFQ, SP+WRR, SP+DRR), RED/WRED, Input/output port-based speed limit |
IPv6 ACL | Support | Support |
Reliability | Control engine, power supply and fan: 1+1 redundancy; Hot-swappable components; Hot patch and online patch upgrade; GR for OSPF/IS-IS/BGP; BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing | Control engine, power supply and fan: 1+1 redundancy; Hot-swappable components; Hot patch and online patch upgrade; GR for OSPF/IS-IS/BGP; BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing |
EEE Format | Support EEE (802.3az) | Support EEE (802.3az) |
Security | NFPP (Network Foundation Protection Policy), CPP (CPU Protection), DAI, Port Security, IP Source Guard, 802.1x, Portal authentication, RADIUS and TACACS+ user login authentication, uRPF, Account privileges and password security policy, Unknown multicasts are not delivered to CPU and support unknown unicasts suppression, Support SSHv2 to provide a secure and encrypted channel for user login | NFPP (Network Foundation Protection Policy), CPP (CPU Protection), DAI, Port Security, IP Source Guard, 802.1x, Portal authentication, RADIUS and TACACS+ user login authentication, uRPF, Account privileges and password security policy, Unknown multicasts are not delivered to CPU and support unknown unicasts suppression, Support SSHv2 to provide a secure and encrypted channel for user login |
Manageability | Console/AUX Modem/Telnet/SSH2.0 command line configuration; FTP, TFTP, Xmodem file upload/download management; SNMP V1/V2c/V3; RMON; NTP clock; Fault alarm and self-recovery; System log; sFlow | Console/AUX Modem/Telnet/SSH2.0 command line configuration; FTP, TFTP, Xmodem file upload/download management; SNMP V1/V2c/V3; RMON; NTP clock; Fault alarm and self-recovery; System log; sFlow |
Hot Patch | Support | Support |
Smart Temperature Control | Fan speed auto-adjustment; Fan malfunction alerts; Fan status check | Fan speed auto-adjustment; Fan malfunction alerts; Fan status check |
Smart Power Supply | Support power control and management | Support power control and management |
Other Protocols | DHCP client, DHCP relay, DHCP server, ARP proxy, Syslog | DHCP client, DHCP relay, DHCP server, ARP proxy, Syslog |
Dimensions | 442mmx 451mmx 175mm,4U | 442mm ×595mm ×439mm, 10U |
Rack Height | 4RU | 10RU |
Weight | 12.42kg (total weight of empty chassis and fans) | 32.35kg (total weight of empty chassis and fans) |
MTBF | 312K hours | 312K hours |
Safety Standards | IEC 60950-1, EN 60950-1 |
|
Emission Standards | EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 | EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 |
Power Supply | RG-PA300I-F:90-290Vac and 1 92-290Vdc ~300W | RG-PA1600I-F:90-180V~1200W;180-264V~ 1600W RG-PA600I-F:90-180V~ 600W;180-264V~ 600W RG-PA1600I-PL:90-175V~1000W;176-264V~1600W RG-PA3000I-PL:90-175V~1200W;176-209V~2500W;210-264V~ :3000W |
Power Consumption | <80W | <176W |
PoE Power Consumption | Non Support | <800W |
Temperature | Operating temperature: 0ºC to 50ºC | Operating temperature: 0ºC to 50ºC |
Storage temperature: -40ºC to 70ºC | Storage temperature: -40ºC to 70ºC |
|
Humidity | Operating humidity: 10% to 90% RH (non-condensing) | Operating humidity: 10% to 90% RH (non-condensing) |
Storage humidity: 5% to 95% RH | Storage humidity: 5% to 95% RH |
|
Operating Altitude | 3,000m to 5,000m | 3,000m to 4,000m |
Select the main chassis and control engine according to specific product model.
Model | Description |
---|---|
RG-S7808C Main Chassis & Control Engine |
|
S7808C | 8-slot Chassis (without power supply) |
M7800C-CM | S7800C Control Engine |
RG-S7805C Main Chassis & Control Engine |
|
RG-S7805C | 5-slot Chassis (without power supply) |
M7805C-CM | S7805C Control Engine |
Select at least 1 power module according to the power supply requirement of the device.
Model | Description |
---|---|
RG-PA300I-F | S7805C Power Module (AC, 300W) |
RG-PA600I-F | S7800C Power Module (support redundancy, AC, 600W, 12V) |
RG-PA1600I-F | S7800C Power Module (support redundancy, AC, 1600W, 12V) |
RG-PA1600I-PL | S7800C PoE Power Module (support redundancy, AC, 1600W, 16A) |
RG-PA3000I-PL | S7800C PoE Power Module (support redundancy, AC, 3000W, 16A) |
M78-PSE | S7800C PoE Box, for RG-PA1600I-PL and RG-PA3000I-PL |
M08-FAN | S7800C Fan, each consists of 2 fan units and 1 fan control board, support side-to-rear airflow (included by default) |
Select the host line cards according to your real application.
Model | Description |
---|---|
Commercial Line Card |
|
M7800C-16SFP8XS-EA | Line Card with 16 Gigabit Ethernet fiber ports (SFP, LC), 8 10G Ethernet fiber ports (SFP+, LC) |
M7800C-24SFP/12GT4XS-EA | Line Card with 24 Gigabit Ethernet fiber ports (SFP, LC), 12 Gigabit Ethernet copper combo ports (RJ45), 4 10G Ethernet fiber ports (SFP+, LC) |
M7800C-36GT12SFP4XS-EA | Line Card with 36 Gigabit Ethernet copper ports (RJ45), 12 Gigabit Ethernet fiber ports (SFP, LC), 4 10G Ethernet fiber ports (SFP+, LC) |
M7800C-48SFP4XS-EA | Line Card with 48 Gigabit Ethernet fiber ports (SFP, LC), 4 10G Ethernet fiber ports (SFP+, LC) |
M7800C-48GT4XS-EA | Line Card with 48 Gigabit Ethernet copper ports (RJ45), 4 10G Ethernet fiber ports (SFP+, LC) |
M7800C-48GT4XS-P-EA | Line Card with 48 Gigabit Ethernet copper ports (RJ45), 4 10G Ethernet fiber ports (SFP+, LC), support PoE/PoE+ |
M7800C-24GT24SFP4XS-EA | Line Card with 24 Gigabit Ethernet copper ports (RJ45), 24 Gigabit Ethernet fiber ports (SFP, LC), 4 10G Ethernet fiber ports (SFP+, LC) |
Model | Description |
---|---|
Mini-GBIC-SX-MM850 | 1000BASE-SX mini GBIC Transceiver (850nm) |
Mini-GBIC-LX-SM1310 | 1000BASE-LX mini GBIC Transceiver (1310nm) |
Mini-GBIC-GT | 1000BASE-GT mini GBIC Transceiver |
Mini-GBIC-LH40-SM1310 | 1000BASE-LH mini GBIC Transceiver (1310nm, 40km) |
Mini-GBIC-ZX50-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 50km) |
Mini-GBIC-ZX80-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 80km) |
Mini-GBIC-ZX100-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 100km) |
XG-SFP-AOC1M | 10GBASE SFP+ Optical Stack Cable (included both side transceivers) , 1 Meter |
XG-SFP-AOC3M | 10GBASE SFP+ Optical Stack Cable (included both side transceivers), 3 Meter |
XG-SFP-AOC5M | 10GBASE SFP+ Optical Stack Cable (included both side transceivers), 5 Meter |
XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ Transceiver (300m) |
XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ Transceiver (10km) |
XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ Transceiver (40km) |
XG-SFP-ZR-SM1550 | 10GBASE-LC, SFP+ Transceiver (80km) |